Catalog navigation
CAD model selection
Selectable products: 1
HELP_VARIABLE
Company
ABB Low Voltage & Systems
Description
AF09 - 3 or 4-pole Contactors - AC or DC Operated
Bill of material
ABB - 1SBL137063R1410 + AF09B-30-10K-14 250-500V50/60HZ-DC Contactor
Product ID
1SBL137063R1410
Extended Product Type
AF09B-30-10K-14
Invoice Description
AF09B-30-10K-14 250-500V50/60HZ-DC Contactor
Description
Push-in Spring Terminals 3 Poles AF Contactor - Top Mounted Coil Terminal
Long Description
AF09B-30-10K-14 250-500V50/60HZ-DC Contactor
International product number
3471523008830
Product number of the Manufacturer
1SBL137063R1410
Rated control supply voltage Us at AC 50HZ
250 - 500 V
Rated control supply voltage Us at AC 60HZ
250 - 500 V
Rated control supply voltage Us at DC
250 - 500 V
Voltage type for actuating
AC/DC
Rated operation current Ie at AC-1, 400 V
25 A
Rated operation current Ie at AC-3, 400 V
9 A
Rated operation power at AC-3, 400 V
4 kW
Rated operation power NEMA
3.7285 kW
Modular version
false
Number of auxiliary contacts as normally open contact
1
Number of auxiliary contacts as normally closed contact
0
Type of electrical connection of main circuit
Spring clamp connection
Number of normally closed contacts as main contact
0
Number of normally open contacts as main contact
3
Type
AF09(Z)B-30-10K
Deeplink product page
Link to product detail page
Procurement
Last updateMay 21, 2025, 4:56 PM
Part number1SBL137063R1410
Currency:
$
£
¥
CN¥
All information without guarantee
Last update: May 21, 2025, 4:56 PM
Preview - Generation
Preview
3D
2D
The preview does not represent the part configuration anymore.You have to generate a new preview.

Classifications
CNS
Object Properties:
Manufacturer / brand name: ABB
Customs Tariff Number: 85364900
Description long: AF09B-30-10K-14 250-500V50/60HZ-DC Contactor
Description short: AF09B-30-10K-14 250-500V50/60HZ-DC Contactor
GTIN-Code: 3471523008830
Order Number: 1SBL137063R1410
Product website: https://new.abb.com/products/ABB1SBL137063R1410
ETIM 8.0
Power contactor, AC switching:
Modular version: false
Rated operation power at AC-3, 400 V: 4 kW
Number of normally open contacts as main contact: 3
Number of normally closed contacts as main contact: 0
Number of auxiliary contacts as normally open contact: 1
Number of auxiliary contacts as normally closed contact: 0
Rated operation current Ie at AC-3, 400 V: 9 A
Rated operation current Ie at AC-1, 400 V: 25 A
Rated control supply voltage Us at AC 50HZ: 250 - 500 V
Rated control supply voltage Us at AC 60HZ: 250 - 500 V
Rated control supply voltage Us at DC: 250 - 500 V
Type of electrical connection of main circuit: Spring clamp connection
Voltage type for actuating: AC/DC
Rated operation power NEMA: 3.7285 kW
ETIM 9.0
Power contactor, AC switching:
Modular version: false
Rated operation power at AC-3, 400 V: 4 kW
Number of normally open contacts as main contact: 3
Number of normally closed contacts as main contact: 0
Number of auxiliary contacts as normally open contact: 1
Number of auxiliary contacts as normally closed contact: 0
Rated operation current Ie at AC-3, 400 V: 9 A
Rated operation current Ie at AC-1, 400 V: 25 A
Rated control supply voltage AC 50 Hz: 250 - 500 V
Rated control supply voltage AC 60 Hz: 250 - 500 V
Rated control supply voltage DC: 250 - 500 V
Type of electrical connection of main circuit: Spring clamp connection
Voltage type for actuating: AC/DC
Rated operation power NEMA: 3.7285 kW
eclass
27-37-10-03 - Power contactor, AC switching:
Rated operating power with AC-3, 400 V: 4 kW
Rated operating current Ie with AC-1, 400 V: 25 A
Rated operating current Ie with AC-3, 400 V: 9 A
max. rated control supply voltage Us: 250 - 500 V
min. rated control voltage Us with AC 50 Hz: 250 - 500 V
min. rated control voltage Us with AC 60 Hz: 250 - 500 V
min. rated control voltage Us with DC: 250 - 500 V
Number of auxiliary contacts as opener: 0
Number of auxiliary contacts as shutter: 1
Number of main contacts as opener: 0
Number of making contacts and main contacts: 3
Type of actuation: AC/DC
Connection type: Spring clamp connection
suitable for series installation: false