Catalog navigation
All catalogs
Geometric Search
CAD model selection
Add for comparison
Selectable products: 1
Company
ABB Low Voltage & Systems
Description
NF - Contactor relays - AC or DC Operated
Bill of material
ABB - 1SBH136001R2359 + NFZ51/11-23 100-250V50/60HZ-DC Contactor relay
Product ID
1SBH136001R2359
Extended Product Type
NFZ51/11-23
Invoice Description
NFZ51/11-23 100-250V50/60HZ-DC Contactor relay
Description
Screw Terminals 8 Poles NF Contactor Relay - Top Mounted Coil Terminal
Long Description
NFZ51/11 contactor relays are used for switching auxiliary and control circuits including overlapping of lagging / leading contacts NFZ contactor relays include an electronic coil interface accepting a wide control voltage Uc min. ... Uc max. Only four coils cover control voltages between 24...250 V 50/60 Hz or 12...250 V DC. NF contactor relays can manage large control voltage variations. One coil can be used for different control voltages used worldwide without any coil change NFZ contactor relays allow direct control by PLC-output ≥ 24 V DC 500 mA and obtain a reduced holding coil consumption. NFZ contactor relays withstand short voltage dips and voltage sags (SEMI F47-0706 compliance) between 24...250 V 50/60 Hz NFZ contactor relays have built-in surge protection and do not require additional surge suppressors - Poles: 8-pole contactor relays with a non-removable front-mounted auxiliary contact block - Control Circuit: AC or DC operated - Accessories: a wide range of Accessories is available.
International product number
3471523107939
Product number of the Manufacturer
1SBH136001R2359
Rated control supply voltage Us at AC 50HZ
100 - 250 V
Rated control supply voltage Us at AC 60HZ
100 - 250 V
Rated control supply voltage Us at DC
100 - 250 V
Voltage type for actuating
AC/DC
Rated operation current Ie, 400 V
3 A
Connection type auxiliary circuit
Screw connection
Mounting method
DIN-rail/screw
Interface
false
Number of auxiliary contacts as normally closed contact, delayed switching
0
Modular version
Number of auxiliary contacts as normally open contact, leading
0
Number of auxiliary contacts as normally open contact
6
Number of auxiliary contacts as change-over contact
0
Number of auxiliary contacts as normally closed contact
2
With LED indication
false
Type of electrical connection of main circuit
Suitable for manual operation
false
Number of normally closed contacts as main contact
Number of normally open contacts as main contact
Customs tariff number
85364900
Type
NF(Z)51/11
Deeplink product page
Link to product detail page
Procurement
Last updateJul 25, 2025, 9:58 AM
Part number1SBH136001R2359
All information without guarantee
Last update: Jul 25, 2025, 9:58 AM
Preview - Generation
Preview
3D
2D
The preview does not represent the part configuration anymore.You have to generate a new preview.

Classifications
ETIM 10.0
Power contactor, AC switching:
Suitable for distribution board:
Number of normally open contacts as main contact:
Number of normally closed contacts as main contact:
Number of auxiliary contacts as normally open contact: 6
Number of auxiliary contacts as normally closed contact: 2
Rated control supply voltage AC 50 Hz: 100 - 250 V
Rated control supply voltage AC 60 Hz: 100 - 250 V
Rated control supply voltage DC: 100 - 250 V
Type of electrical connection of main circuit:
Voltage type for actuating: AC/DC
Auxiliary contactor, relay:
Mounting method: DIN-rail/screw
Interface: false
Number of auxiliary contacts as normally open contact: 6
Number of auxiliary contacts as normally closed contact: 2
Rated operation current Ie, 400 V: 3 A
Suitable for manual operation: false
Number of auxiliary contacts as change-over contact: 0
Rated control supply voltage AC 50 Hz: 100 - 250 V
Rated control supply voltage AC 60 Hz: 100 - 250 V
Rated control supply voltage DC: 100 - 250 V
With LED indication: false
Connection type auxiliary circuit: Screw connection
Number of auxiliary contacts as normally closed contact, delayed switching: 0
Number of auxiliary contacts as normally open contact, leading: 0
Voltage type for actuating: AC/DC
CNS
Object Properties:
Manufacturer / brand name: ABB
Customs Tariff Number: 85364900
Description long: NFZ51/11 contactor relays are used for switching auxiliary and control circuits including overlapping of lagging / leading contacts NFZ contactor relays include an electronic coil interface accepting a wide control voltage Uc min. ... Uc max. Only four coils cover control voltages between 24...250 V 50/60 Hz or 12...250 V DC. NF contactor relays can manage large control voltage variations. One coil can be used for different control voltages used worldwide without any coil change NFZ contactor relays allow direct control by PLC-output ≥ 24 V DC 500 mA and obtain a reduced holding coil consumption. NFZ contactor relays withstand short voltage dips and voltage sags (SEMI F47-0706 compliance) between 24...250 V 50/60 Hz NFZ contactor relays have built-in surge protection and do not require additional surge suppressors - Poles: 8-pole contactor relays with a non-removable front-mounted auxiliary contact block - Control Circuit: AC or DC operated - Accessories: a wide range of Accessories is available.
Description short: NFZ51/11-23 100-250V50/60HZ-DC Contactor relay
GTIN-Code: 3471523107939
Order Number: 1SBH136001R2359
Product website: https://new.abb.com/products/ABB1SBH136001R2359
ETIM 8.0
Power contactor, AC switching:
Modular version:
Number of normally open contacts as main contact:
Number of normally closed contacts as main contact:
Number of auxiliary contacts as normally open contact: 6
Number of auxiliary contacts as normally closed contact: 2
Rated control supply voltage Us at AC 50HZ: 100 - 250 V
Rated control supply voltage Us at AC 60HZ: 100 - 250 V
Rated control supply voltage Us at DC: 100 - 250 V
Type of electrical connection of main circuit:
Voltage type for actuating: AC/DC
Contactor relay:
Mounting method: DIN-rail/screw
Interface: false
Number of auxiliary contacts as normally open contact: 6
Number of auxiliary contacts as normally closed contact: 2
Rated operation current Ie, 400 V: 3 A
Suitable for manual operation: false
Number of auxiliary contacts as change-over contact: 0
Rated control supply voltage Us at AC 50HZ: 100 - 250 V
Rated control supply voltage Us at AC 60HZ: 100 - 250 V
Rated control supply voltage Us at DC: 100 - 250 V
With LED indication: false
Connection type auxiliary circuit: Screw connection
Number of auxiliary contacts as normally closed contact, delayed switching: 0
Number of auxiliary contacts as normally open contact, leading: 0
Voltage type for actuating: AC/DC
ETIM 9.0
Power contactor, AC switching:
Modular version:
Number of normally open contacts as main contact:
Number of normally closed contacts as main contact:
Number of auxiliary contacts as normally open contact: 6
Number of auxiliary contacts as normally closed contact: 2
Rated control supply voltage AC 50 Hz: 100 - 250 V
Rated control supply voltage AC 60 Hz: 100 - 250 V
Rated control supply voltage DC: 100 - 250 V
Type of electrical connection of main circuit:
Voltage type for actuating: AC/DC
Contactor relay:
Mounting method: DIN-rail/screw
Interface: false
Number of auxiliary contacts as normally open contact: 6
Number of auxiliary contacts as normally closed contact: 2
Rated operation current Ie, 400 V: 3 A
Suitable for manual operation: false
Number of auxiliary contacts as change-over contact: 0
Rated control supply voltage AC 50 Hz: 100 - 250 V
Rated control supply voltage AC 60 Hz: 100 - 250 V
Rated control supply voltage DC: 100 - 250 V
With LED indication: false
Connection type auxiliary circuit: Screw connection
Number of auxiliary contacts as normally closed contact, delayed switching: 0
Number of auxiliary contacts as normally open contact, leading: 0
Voltage type for actuating: AC/DC
eclass
27-37-10-01 - Contactor relay:
Rated operating current Ie, 400 V: 3 A
max. rated control supply voltage Us: 100 - 250 V
min. rated control voltage Us with AC 50 Hz: 100 - 250 V
min. rated control voltage Us with AC 60 Hz: 100 - 250 V
min. rated control voltage Us with DC: 100 - 250 V
interface present: false
manual operation possible: false
number of auxiliary contacts as normally closed contact, delayed switching: 0
Number of auxiliary contacts as changer: 0
Number of auxiliary contacts as make contacts, leading: 0
Number of auxiliary contacts as opener: 2
Number of auxiliary contacts as shutter: 6
Type of actuation: AC/DC
Connection type: Screw connection
LED display present: false
Assembly type: DIN-rail/screw
27-37-10-03 - Power contactor, AC switching:
max. rated control supply voltage Us: 100 - 250 V
min. rated control voltage Us with AC 50 Hz: 100 - 250 V
min. rated control voltage Us with AC 60 Hz: 100 - 250 V
min. rated control voltage Us with DC: 100 - 250 V
Number of auxiliary contacts as opener: 2
Number of auxiliary contacts as shutter: 6
Number of main contacts as opener:
Number of making contacts and main contacts:
Type of actuation: AC/DC
Connection type:
suitable for series installation: