Catalog navigation
All catalogs
Geometric Search
CAD model selection
Add for comparison
Selectable products: 1
Company
ABB Low Voltage & Systems
Description
NSL - Contactor relays - DC Operated
Bill of material
ABB - 1SBH103001R8140 + NSL40E-81 24VDC Contactor Relay
Product ID
1SBH103001R8140
Extended Product Type
NSL40E-81
Invoice Description
NSL40E-81 24VDC Contactor Relay
Description
Screw terminals
Long Description
NSL... contactor relays are used for switching auxiliary circuits and control circuits. - Poles and auxiliary contacts blocks: 4-pole contactor relays, front-mounted add-on auxiliary contact blocks (mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1) - Control circuit: DC operated with solid core magnet circuit. The polarity on the coil terminals (A1+ and A2-) must be respected - Accessories: a wide range of accessories is available NSL... contactors are fitted with low consumption DC coils and are suitable for a direct control by PLC outputs.
International product number
3471523056213
Product number of the Manufacturer
1SBH103001R8140
Rated control supply voltage Us at AC 50HZ
- - - V
Rated control supply voltage Us at AC 60HZ
- - - V
Rated control supply voltage Us at DC
24 - 24 V
Voltage type for actuating
DC
Rated operation current Ie, 400 V
3 A
Connection type auxiliary circuit
Screw connection
Mounting method
DIN-rail/screw
Interface
false
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
4
Number of auxiliary contacts as normally closed contact, delayed switching
0
Number of auxiliary contacts as normally open contact, leading
0
Number of auxiliary contacts as change-over contact
0
With LED indication
false
Suitable for manual operation
false
Customs tariff number
85364900
Deeplink product page
Link to product detail page
Type
NSL40E
Procurement
Last updateJul 25, 2025, 9:58 AM
Part number1SBH103001R8140
All information without guarantee
Last update: Jul 25, 2025, 9:58 AM
Preview - Generation
Preview
3D
2D
The preview does not represent the part configuration anymore.You have to generate a new preview.

Classifications
ETIM 10.0
Auxiliary contactor, relay:
Mounting method: DIN-rail/screw
Interface: false
Number of auxiliary contacts as normally open contact: 4
Number of auxiliary contacts as normally closed contact: 0
Rated operation current Ie, 400 V: 3 A
Suitable for manual operation: false
Number of auxiliary contacts as change-over contact: 0
Rated control supply voltage AC 50 Hz: - - - V
Rated control supply voltage AC 60 Hz: - - - V
Rated control supply voltage DC: 24 - 24 V
With LED indication: false
Connection type auxiliary circuit: Screw connection
Number of auxiliary contacts as normally closed contact, delayed switching: 0
Number of auxiliary contacts as normally open contact, leading: 0
Voltage type for actuating: DC
CNS
Object Properties:
Order Number: 1SBH103001R8140
Description long: NSL... contactor relays are used for switching auxiliary circuits and control circuits. - Poles and auxiliary contacts blocks: 4-pole contactor relays, front-mounted add-on auxiliary contact blocks (mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1) - Control circuit: DC operated with solid core magnet circuit. The polarity on the coil terminals (A1+ and A2-) must be respected - Accessories: a wide range of accessories is available NSL... contactors are fitted with low consumption DC coils and are suitable for a direct control by PLC outputs.
Description short: NSL40E-81 24VDC Contactor Relay
Manufacturer / brand name: ABB
Product website: https://new.abb.com/products/ABB1SBH103001R8140
Customs Tariff Number: 85364900
GTIN-Code: 3471523056213
ETIM 8.0
Contactor relay:
Mounting method: DIN-rail/screw
Interface: false
Number of auxiliary contacts as normally open contact: 4
Number of auxiliary contacts as normally closed contact: 0
Rated operation current Ie, 400 V: 3 A
Suitable for manual operation: false
Number of auxiliary contacts as change-over contact: 0
Rated control supply voltage Us at AC 50HZ: - - - V
Rated control supply voltage Us at AC 60HZ: - - - V
Rated control supply voltage Us at DC: 24 - 24 V
With LED indication: false
Connection type auxiliary circuit: Screw connection
Number of auxiliary contacts as normally closed contact, delayed switching: 0
Number of auxiliary contacts as normally open contact, leading: 0
Voltage type for actuating: DC
ETIM 9.0
Contactor relay:
Mounting method: DIN-rail/screw
Interface: false
Number of auxiliary contacts as normally open contact: 4
Number of auxiliary contacts as normally closed contact: 0
Rated operation current Ie, 400 V: 3 A
Suitable for manual operation: false
Number of auxiliary contacts as change-over contact: 0
Rated control supply voltage AC 50 Hz: - - - V
Rated control supply voltage AC 60 Hz: - - - V
Rated control supply voltage DC: 24 - 24 V
With LED indication: false
Connection type auxiliary circuit: Screw connection
Number of auxiliary contacts as normally closed contact, delayed switching: 0
Number of auxiliary contacts as normally open contact, leading: 0
Voltage type for actuating: DC
cadenas_class
:
eclass
27-37-10-01 - Contactor relay:
Rated operating current Ie, 400 V: 3 A
max. rated control supply voltage Us: - - - V
min. rated control voltage Us with AC 50 Hz: - - - V
min. rated control voltage Us with AC 60 Hz: - - - V
min. rated control voltage Us with DC: 24 - 24 V
interface present: false
manual operation possible: false
number of auxiliary contacts as normally closed contact, delayed switching: 0
Number of auxiliary contacts as changer: 0
Number of auxiliary contacts as make contacts, leading: 0
Number of auxiliary contacts as opener: 0
Number of auxiliary contacts as shutter: 4
Type of actuation: DC
Connection type: Screw connection
LED display present: false
Assembly type: DIN-rail/screw