ABB Low Voltage & Systems
Description
MO132 - Manual Motor Starters
Bill of material
ABB - 1SAM360000R1015 + MO132-32 Manual Motor Starter Magnetic only, 32A
Sellers P/N
1SAM360000R1015
Extended Product Type
MO132-32
Invoice Description
MO132-32 Manual Motor Starter Magnetic only, 32A
Sellers P/N
Manual Motor Starter Magnetic Only
Type
MO132-32
Description
Manual Motor Starter Magnetic Only
Ampere Rating UL/CSA
32.00 A
ATEX Certificate
-
Connecting Capacity Main Circuit Header
Flexible with Ferrule
Flexible with Insulated Ferrule
Flexible 2.5
Flexible 6
Rigid 2.5
Rigid 6
Connecting Capacity Main Circuit Value
1/2x 0.75 ... 6 mm²
Customs tariff number
85362010
Electrical Durability
50000 Cycle
ETIM 6
EC000074 - Motor protection circuit-breaker
Mechanical Durability
100000 Cycle
Mounted Auxiliary Contacts
-
Phase Loss Sensitive
No
Power Loss Header
at Rated Operating Conditions per Pole
Power Loss Value
3.1 W
Product Net Weight
0.310 kg
Rated Current
32.00 A
Rated Instantaneous Short-Circuit Current Setting
400.00 A
Rated Insulation Voltage
690 V
Rated Operational Power AC-3 Header
(400 V) Three Phase
Rated Operational Power AC-3 Value
15.00 kW
Rated Operational Voltage Header
Main Circuit
Rated Operational Voltage Value
690 V
Rated Service Short-Circuit Breaking Capacity Header
(230 V AC)
(400 V AC)
(440 V AC)
(500 V AC)
(690 V AC)
Rated Service Short-Circuit Breaking Capacity Value
230.000 kA
Rated Ultimate Short-Circuit Breaking Capacity Header
(230 V AC)
(400 V AC)
(440 V AC)
(500 V AC)
(690 V AC)
Rated Ultimate Short-Circuit Breaking Capacity Value
100.000 kA
Rated Uninterrupted Current
32.00 A
Setting Range
-
Trip Class
-
UNSPSC
39121521
Short Description
MO132-32 Manual Motor Starter
Long Description
The MO132-32 manual motor starter magnetic only is a compact 45 mm width device with a rated operational current of Ie = 32.0 A. This device is used to manually switch on and off loads/motors and to protect them reliably and without the need for a fuse from short-circuits. The manual motor starter offers a rated service short-circuit breaking capacity Ics = 30 kA at 400 V AC. A combination together with overload relays or motor controllers allows the protection of motors. Further features are the built-in disconnect function, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter magnetic only is suitable for three- and single-phase applications. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signalling contacts, undervoltage releases, shunt trips, 3-phase bus bars, power in-feed blocks are available as accessory.
International product number
4013614400308
Product number of the Manufacturer
1SAM360000R1015
Manufacturer Name
ABB
Overload release current setting
32, 32 A
Adjustment range undelayed short-circuit release
400, 400 A
With thermal protection
false
Phase failure sensitive
false
Switch off technique
Magnetic
Rated operating voltage
690, 690 V
Rated permanent current Iu
32 A
Rated operation power at AC-3, 400 V
15 kW
Type of electrical connection of main circuit
Screw connection
Type of control element
Turn button
Device construction
Complete device in housing
With integrated auxiliary switch
false
With integrated under voltage release
false
Number of poles
3
Rated short-circuit breaking capacity lcu at 400 V, AC
50 kA
Degree of protection (IP)
IP20
Height
97.8 mm
Width
45 mm
Depth
86.55 mm
Deeplink product page
Link to product detail page
Preview - Generation
Preview
3D
2D
The preview does not represent the part configuration anymore.You have to generate a new preview.

Classifications
ETIM 10.0
Motor protection circuit-breaker:
Width: 45 mm
Height: 97.8 mm
Depth: 86.55 mm
Rated operation power at AC-3, 400 V: 15 kW
With integrated auxiliary switch: false
Rated permanent current Iu: 32 A
With integrated under voltage release: false
Number of poles: 3
Rated operating voltage: 690, 690 V
Overload release current setting: 32, 32 A
Degree of protection (IP): IP20
With thermal overload protection: false
Type of electrical connection of main circuit: Screw connection
Type of control element: Turn button
Switch off technique: Magnetic
Rated short-circuit breaking capacity Icu at 400 V, AC: 50 kA
Adjustment range undelayed short-circuit release: 400, 400 A
Phase failure sensitive: false
Device construction: Complete device in housing
CNS
Object Properties:
Order Number: 1SAM360000R1015MO132-32 Manual Motor Starter Magnetic only, 32A
Description long: The MO132-32 manual motor starter magnetic only is a compact 45 mm width device with a rated operational current of Ie = 32.0 A. This device is used to manually switch on and off loads/motors and to protect them reliably and without the need for a fuse from short-circuits. The manual motor starter offers a rated service short-circuit breaking capacity Ics = 30 kA at 400 V AC. A combination together with overload relays or motor controllers allows the protection of motors. Further features are the built-in disconnect function, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter magnetic only is suitable for three- and single-phase applications. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signalling contacts, undervoltage releases, shunt trips, 3-phase bus bars, power in-feed blocks are available as accessory.
Description short: MO132-32 Manual Motor Starter
Manufacturer / brand name: ABB
Product website: https://new.abb.com/products/ABB1SAM360000R1015
Customs Tariff Number: 85362010
GTIN-Code: 4013614400308
ETIM 8.0
Motor protection circuit-breaker:
Width: 45 mm
Height: 97.8 mm
Depth: 86.55 mm
Rated operation power at AC-3, 400 V: 15 kW
With integrated auxiliary switch: false
Rated permanent current Iu: 32 A
With integrated under voltage release: false
Number of poles: 3
Rated operating voltage: 690, 690 V
Overload release current setting: 32, 32 A
Degree of protection (IP): IP20
With thermal protection: false
Type of electrical connection of main circuit: Screw connection
Type of control element: Turn button
Switch off technique: Magnetic
Rated short-circuit breaking capacity lcu at 400 V, AC: 50 kA
Adjustment range undelayed short-circuit release: 400, 400 A
Phase failure sensitive: false
Device construction: Complete device in housing
ETIM 9.0
Motor protection circuit-breaker:
Width: 45 mm
Height: 97.8 mm
Depth: 86.55 mm
Rated operation power at AC-3, 400 V: 15 kW
With integrated auxiliary switch: false
Rated permanent current Iu: 32 A
With integrated under voltage release: false
Number of poles: 3
Rated operating voltage: 690, 690 V
Overload release current setting: 32, 32 A
Degree of protection (IP): IP20
With thermal overload protection: false
Type of electrical connection of main circuit: Screw connection
Type of control element: Turn button
Switch off technique: Magnetic
Rated short-circuit breaking capacity lcu at 400 V, AC: 50 kA
Adjustment range undelayed short-circuit release: 400, 400 A
Phase failure sensitive: false
Device construction: Complete device in housing
eclass
27-37-04-01 - Motor protection circuit-breaker:
Release system: Magnetic
Rated operating power with AC-3, 400 V: 15 kW
rated permanent current: 32 A
rated limit short-circuit switch-off current Icu with 400 V, 50 AC: 50 kA
Greatest value of overload release adjustment range: 32, 32 A
Device type: Complete device in housing
Sensitive to phase failure: false
Lowest value of setting range for overload tripper: 32, 32 A
Lowest value of setting range for short circuit tripper, undelayed: 400, 400 A
Greatest value of tuning range short circuit tripper, undelayed: 400, 400 A
rated current: 690, 690 V
min. rated operating voltage: 690, 690 V
thermal protection present: false
Pole number: 3
height: 97.8 mm
depth: 86.55 mm
Connection type: Screw connection
Integrated auxiliary switch present: false
Integrated undervoltage tripper present: false
Design of actuating element: Turn button
width: 45 mm
degree of protection: IP20