ABB Low Voltage & Systems
Description
MS165 - Manual Motor Starters
Bill of material
ABB - 1SAM451000R1019 + MS165-80 Manual motor starter Trip class 10, 70 - 80 A
Product Id
1SAM451000R1019
Extended Product Type
MS165-80
Invoice Description
MS165-80 Manual motor starter Trip class 10, 70 - 80 A
Type
MS165
Description
Manual Motor Starter, Ie = 16 - 65 A
Short Description
MS165-80 Manual motor starter
Long Description
MS165 is a compact and powerful range for motor protection up to 45 kW (400 V) / 80 A in width of 55 mm. They offer a reliable protection for motors in the event of overload or phase failure. The devices have trip class 10. This type has also a clear and reliable indication of fault in a separate window in the event of short-circuit tripping. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter (also known as motor protection circuit breaker or manual motor protector) is suitable for three- and single phase applications. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signaling contacts, undervoltage releases, shunt trips, power in-feed blocks are available as accessory. These are suitable throughout the MS116/MS132/MS165 range.
International product number
4013614536632
Product number of the Manufacturer
1SAM451000R1019
Manufacturer Name
ABB
Overload release current setting
70, 80 A
Adjustment range undelayed short-circuit release
1120, 1120 A
With thermal protection
true
Phase failure sensitive
true
Switch off technique
Thermomagnetic
Rated operating voltage
250, 690 V
Rated permanent current Iu
80 A
Rated operation power at AC-3, 400 V
45 kW
Type of electrical connection of main circuit
Screw connection
Type of control element
Turn button
Device construction
Complete device in housing
With integrated auxiliary switch
false
With integrated under voltage release
false
Number of poles
3
Rated short-circuit breaking capacity lcu at 400 V, AC
30 kA
Degree of protection (IP)
IP20
Height
142.65 mm
Width
55 mm
Depth
122 mm
Deeplink product page
Link to product detail page
Procurement
Last updateJul 25, 2025, 10:02 AM
Part number1SAM451000R1019
All information without guarantee
Last update: Jul 25, 2025, 10:02 AM
Preview - Generation
Preview
3D
2D
The preview does not represent the part configuration anymore.You have to generate a new preview.

Classifications
ETIM 10.0
Motor protection circuit-breaker:
Width: 55 mm
Height: 142.65 mm
Depth: 122 mm
Rated operation power at AC-3, 400 V: 45 kW
With integrated auxiliary switch: false
Rated permanent current Iu: 80 A
With integrated under voltage release: false
Number of poles: 3
Rated operating voltage: 250, 690 V
Overload release current setting: 70, 80 A
Degree of protection (IP): IP20
With thermal overload protection: true
Type of electrical connection of main circuit: Screw connection
Type of control element: Turn button
Switch off technique: Thermomagnetic
Rated short-circuit breaking capacity Icu at 400 V, AC: 30 kA
Adjustment range undelayed short-circuit release: 1120, 1120 A
Phase failure sensitive: true
Device construction: Complete device in housing
CNS
Object Properties:
Manufacturer / brand name: ABB
Customs Tariff Number: 85362090
Description long: MS165 is a compact and powerful range for motor protection up to 45 kW (400 V) / 80 A in width of 55 mm. They offer a reliable protection for motors in the event of overload or phase failure. The devices have trip class 10. This type has also a clear and reliable indication of fault in a separate window in the event of short-circuit tripping. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter (also known as motor protection circuit breaker or manual motor protector) is suitable for three- and single phase applications. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signaling contacts, undervoltage releases, shunt trips, power in-feed blocks are available as accessory. These are suitable throughout the MS116/MS132/MS165 range.
Description short: MS165-80 Manual motor starter
Order Number: 1SAM451000R1019
Product website: https://new.abb.com/products/ABB1SAM451000R1019
GTIN-Code: 4013614536632
ETIM 8.0
Motor protection circuit-breaker:
Width: 55 mm
Height: 142.65 mm
Depth: 122 mm
Rated operation power at AC-3, 400 V: 45 kW
With integrated auxiliary switch: false
Rated permanent current Iu: 80 A
With integrated under voltage release: false
Number of poles: 3
Rated operating voltage: 250, 690 V
Overload release current setting: 70, 80 A
Degree of protection (IP): IP20
With thermal protection: true
Type of electrical connection of main circuit: Screw connection
Type of control element: Turn button
Switch off technique: Thermomagnetic
Rated short-circuit breaking capacity lcu at 400 V, AC: 30 kA
Adjustment range undelayed short-circuit release: 1120, 1120 A
Phase failure sensitive: true
Device construction: Complete device in housing
ETIM 9.0
Motor protection circuit-breaker:
Width: 55 mm
Height: 142.65 mm
Depth: 122 mm
Rated operation power at AC-3, 400 V: 45 kW
With integrated auxiliary switch: false
Rated permanent current Iu: 80 A
With integrated under voltage release: false
Number of poles: 3
Rated operating voltage: 250, 690 V
Overload release current setting: 70, 80 A
Degree of protection (IP): IP20
With thermal overload protection: true
Type of electrical connection of main circuit: Screw connection
Type of control element: Turn button
Switch off technique: Thermomagnetic
Rated short-circuit breaking capacity lcu at 400 V, AC: 30 kA
Adjustment range undelayed short-circuit release: 1120, 1120 A
Phase failure sensitive: true
Device construction: Complete device in housing
eclass
27-37-04-01 - Motor protection circuit-breaker:
Release system: Thermomagnetic
Rated operating power with AC-3, 400 V: 45 kW
rated permanent current: 80 A
rated limit short-circuit switch-off current Icu with 400 V, 50 AC: 30 kA
Greatest value of overload release adjustment range: 70, 80 A
Device type: Complete device in housing
Sensitive to phase failure: true
Lowest value of setting range for overload tripper: 70, 80 A
Lowest value of setting range for short circuit tripper, undelayed: 1120, 1120 A
Greatest value of tuning range short circuit tripper, undelayed: 1120, 1120 A
rated current: 250, 690 V
min. rated operating voltage: 250, 690 V
thermal protection present: true
Pole number: 3
height: 142.65 mm
depth: 122 mm
Connection type: Screw connection
Integrated auxiliary switch present: false
Integrated undervoltage tripper present: false
Design of actuating element: Turn button
width: 55 mm
degree of protection: IP20