Catalog navigation
All catalogs
Geometric Search
CAD model selection
Add for comparison
Selectable products: 1
Company
ABB Low Voltage & Systems
Description
MS132 - Manual Motor Starters
Bill of material
ABB - 1SAM350200R1006 + MS132-1.6B Manual Motor Starter for Railway
Product Id
1SAM350200R1006
Extended Product Type
MS132-1.6B
Invoice Description
MS132-1.6B Manual Motor Starter for Railway
Type
MS132, Ie = < 10 A
Description
Manual Motor Starter, Ie = 0.16 ... 10 A
Short Description
MS132-1.6B Manual Motor Starter
Long Description
MS132-B is a compact and powerful range for motor protection up to 15 kW (400 V) / 32 A in width of 45 mm, complying with the latest railway rolling stock standards and allowing installation in passengers or driver cabins for trains frequently operating tunnels or undergrounds. They offer a reliable protection for motors in the event of overload or phase failure. The devices have trip class 10. This type has also a clear and reliable indication of fault in a separate window in the event of short-circuit tripping. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter is suitable for three- and single phase applications. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signaling contacts, undervoltage releases, shunt trips, power in-feed blocks are available as accessory. These are suitable throughout the MS132-B/MS165-B range. – designed in accordance to the applicable parts of IEC 60077 standard – shocks and vibration withstand conforming to IEC 61373 (category 1, class B) – usable according to European fire and smoke safety standard EN 45545-2
International product number
4013614521362
Product number of the Manufacturer
1SAM350200R1006
Manufacturer Name
ABB
Rated voltage
V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
kA
With thermal protection
true
Phase failure sensitive
true
Overload release current setting
1.0, 1.6 A
Adjustment range short-term delayed short-circuit release
A
Switch off technique
Thermomagnetic
Rated operating voltage
250, 690 V
Adjustment range undelayed short-circuit release
20, 20 A
Rated permanent current Iu
1.6 A
Rated operation power at AC-3, 400 V
0.55 kW
Type of electrical connection of main circuit
Screw connection
Type of control element
Turn button
Device construction
Complete device in housing
With integrated auxiliary switch
false
With integrated under voltage release
false
Number of poles
3
Rated short-circuit breaking capacity lcu at 400 V, AC
100 kA
Degree of protection (IP)
IP20
Height
90 mm
Width
45 mm
Depth
86.75 mm
Customs tariff number
85362010
EFI00040
EFI00008
EFI00049
Deeplink product page
Link to product detail page
Procurement
Last updateJul 25, 2025, 10:01 AM
Part number1SAM350200R1006
All information without guarantee
Last update: Jul 25, 2025, 10:01 AM
Preview - Generation
Preview
3D
2D
The preview does not represent the part configuration anymore.You have to generate a new preview.

Classifications
ETIM 10.0
Motor protection circuit-breaker:
Width: 45 mm
Height: 90 mm
Depth: 86.75 mm
Rated operation power at AC-3, 400 V: 0.55 kW
With integrated auxiliary switch: false
Rated permanent current Iu: 1.6 A
With integrated under voltage release: false
Number of poles: 3
Rated operating voltage: 250, 690 V
Overload release current setting: 1.0, 1.6 A
Degree of protection (IP): IP20
With thermal overload protection: true
Type of electrical connection of main circuit: Screw connection
Type of control element: Turn button
Switch off technique: Thermomagnetic
Rated short-circuit breaking capacity Icu at 400 V, AC: 100 kA
Adjustment range undelayed short-circuit release: 20, 20 A
Phase failure sensitive: true
Device construction: Complete device in housing
Power circuit-breaker for trafo/generator/installation protection:
Rated permanent current Iu: 1.6 A
Overload release current setting: 1.0, 1.6 A
Rated voltage: V
Rated short-circuit breaking capacity Icu at 400 V, 50 Hz: kA
Adjustment range short-term delayed short-circuit release: A
Adjustment range undelayed short-circuit release: 20, 20 A
CNS
Object Properties:
Manufacturer / brand name: ABB
Customs Tariff Number: 85362010
Description long: MS132-B is a compact and powerful range for motor protection up to 15 kW (400 V) / 32 A in width of 45 mm, complying with the latest railway rolling stock standards and allowing installation in passengers or driver cabins for trains frequently operating tunnels or undergrounds. They offer a reliable protection for motors in the event of overload or phase failure. The devices have trip class 10. This type has also a clear and reliable indication of fault in a separate window in the event of short-circuit tripping. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter is suitable for three- and single phase applications. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signaling contacts, undervoltage releases, shunt trips, power in-feed blocks are available as accessory. These are suitable throughout the MS132-B/MS165-B range. – designed in accordance to the applicable parts of IEC 60077 standard – shocks and vibration withstand conforming to IEC 61373 (category 1, class B) – usable according to European fire and smoke safety standard EN 45545-2
Description short: MS132-1.6B Manual Motor Starter
GTIN-Code: 4013614521362
Order Number: 1SAM350200R1006
Product website: https://new.abb.com/products/ABB1SAM350200R1006
ETIM 8.0
Motor protection circuit-breaker:
Width: 45 mm
Height: 90 mm
Depth: 86.75 mm
Rated operation power at AC-3, 400 V: 0.55 kW
With integrated auxiliary switch: false
Rated permanent current Iu: 1.6 A
With integrated under voltage release: false
Number of poles: 3
Rated operating voltage: 250, 690 V
Overload release current setting: 1.0, 1.6 A
Degree of protection (IP): IP20
With thermal protection: true
Type of electrical connection of main circuit: Screw connection
Type of control element: Turn button
Switch off technique: Thermomagnetic
Rated short-circuit breaking capacity lcu at 400 V, AC: 100 kA
Adjustment range undelayed short-circuit release: 20, 20 A
Phase failure sensitive: true
Device construction: Complete device in housing
Power circuit-breaker for trafo/generator/installation protection:
Rated permanent current Iu: 1.6 A
Overload release current setting: 1.0, 1.6 A
Rated voltage: V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: kA
Adjustment range short-term delayed short-circuit release: A
Adjustment range undelayed short-circuit release: 20, 20 A
ETIM 9.0
Motor protection circuit-breaker:
Width: 45 mm
Height: 90 mm
Depth: 86.75 mm
Rated operation power at AC-3, 400 V: 0.55 kW
With integrated auxiliary switch: false
Rated permanent current Iu: 1.6 A
With integrated under voltage release: false
Number of poles: 3
Rated operating voltage: 250, 690 V
Overload release current setting: 1.0, 1.6 A
Degree of protection (IP): IP20
With thermal overload protection: true
Type of electrical connection of main circuit: Screw connection
Type of control element: Turn button
Switch off technique: Thermomagnetic
Rated short-circuit breaking capacity lcu at 400 V, AC: 100 kA
Adjustment range undelayed short-circuit release: 20, 20 A
Phase failure sensitive: true
Device construction: Complete device in housing
Power circuit-breaker for trafo/generator/installation protection:
Rated permanent current Iu: 1.6 A
Overload release current setting: 1.0, 1.6 A
Rated voltage: V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: kA
Adjustment range short-term delayed short-circuit release: A
Adjustment range undelayed short-circuit release: 20, 20 A
eclass
27-37-04-01 - Motor protection circuit-breaker:
Release system: Thermomagnetic
Rated operating power with AC-3, 400 V: 0.55 kW
rated permanent current: 1.6 A
rated limit short-circuit switch-off current Icu with 400 V, 50 AC: 100 kA
Greatest value of overload release adjustment range: 1.0, 1.6 A
Device type: Complete device in housing
Sensitive to phase failure: true
Lowest value of setting range for overload tripper: 1.0, 1.6 A
Lowest value of setting range for short circuit tripper, undelayed: 20, 20 A
Greatest value of tuning range short circuit tripper, undelayed: 20, 20 A
rated current: 250, 690 V
min. rated operating voltage: 250, 690 V
thermal protection present: true
Pole number: 3
height: 90 mm
depth: 86.75 mm
Connection type: Screw connection
Integrated auxiliary switch present: false
Integrated undervoltage tripper present: false
Design of actuating element: Turn button
width: 45 mm
degree of protection: IP20
27-37-04-09 - Circuit breaker for power transformer, generator and system protection:
lowest value for short-time delayed short-circuit release adjustment range: A
rated permanent current: 1.6 A
rated limit short-circuit switch-off current Icu with 400 V, 50 Hz: kA
greatest value of short-time delayed short-circuit release adjustment range: A
Greatest value of overload release adjustment range: 1.0, 1.6 A
Lowest value of setting range for overload tripper: 1.0, 1.6 A
Lowest value of setting range for short circuit tripper, undelayed: 20, 20 A
Greatest value of tuning range short circuit tripper, undelayed: 20, 20 A
Max. rated voltage: V
Min. rated voltage: V