Catalog navigation
All catalogs
Geometric Search
CAD model selection
Add for comparison
Selectable products: 1
Company
ABB Low Voltage & Systems
Description
AA1 - Shunt Trip
Bill of material
ABB - 1SAM201910R1004 + AA1-400 Shunt Trip 350-415V
Product Id
1SAM201910R1004
Extended Product Type
AA1-400
Invoice Description
AA1-400 Shunt Trip 350-415V
Type
AA1
Description
Shunt Trip, for lateral mounting at the left
Short Description
AA1-400 Shunt Trip 350-415V
Long Description
Shunt trips AA1 release manual motor starters used for remote tripping. They are attached laterally on the left side of MS116, MS132 or MS165. In accordance with IEC 60947-1, the manual motor starter is switched off by AA1 if the supply voltage of the shunt trip measured during the tripping operation remains between 70% and 110% of the rated control circuit supply voltage.
International product number
4013614343360
Product number of the Manufacturer
1SAM201910R1004
Manufacturer Name
ABB
Rated control supply voltage Us at AC 50HZ
350, 415 V
Rated control supply voltage Us at AC 60HZ
350, 415 V
Rated control supply voltage Us at DC
350, 500 V
Voltage type for actuating
AC/DC
Initial value of the undelayed short-circuit release - setting range
0 A
End value adjustment range undelayed short-circuit release
0 A
Type of electric connection
Screw connection
Number of contacts as normally open contact
0
Number of contacts as normally closed contact
0
Number of contacts as change-over contact
0
Suitable for power circuit breaker
false
Suitable for off-load switch
false
Suitable for motor safety switch
true
Suitable for overload relay
false
Customs tariff number
85365080
Deeplink product page
Link to product detail page
Procurement
Last updateJul 25, 2025, 10:05 AM
Part number1SAM201910R1004
All information without guarantee
Last update: Jul 25, 2025, 10:05 AM
Preview - Generation
Preview
3D
2D
The preview does not represent the part configuration anymore.You have to generate a new preview.

Classifications
ETIM 10.0
Shunt release (for power circuit breaker):
Suitable for off-load switch: false
Suitable for overload relay: false
Type of electric connection: Screw connection
Rated control supply voltage AC 50 Hz: 350, 415 V
Rated control supply voltage AC 60 Hz: 350, 415 V
Rated control supply voltage DC: 350, 500 V
Suitable for motor safety switch: true
Suitable for power circuit breaker: false
Initial value of the undelayed short-circuit release - setting range: 0 A
End value adjustment range undelayed short-circuit release: 0 A
Voltage type for actuating: AC/DC
Number of contacts as normally closed contact: 0
Number of contacts as normally open contact: 0
Number of contacts as change-over contact: 0
CNS
Object Properties:
Order Number: 1SAM201910R1004
Description long: Shunt trips AA1 release manual motor starters used for remote tripping. They are attached laterally on the left side of MS116, MS132 or MS165. In accordance with IEC 60947-1, the manual motor starter is switched off by AA1 if the supply voltage of the shunt trip measured during the tripping operation remains between 70% and 110% of the rated control circuit supply voltage.
Description short: AA1-400 Shunt Trip 350-415V
Manufacturer / brand name: ABB
Product website: https://new.abb.com/products/ABB1SAM201910R1004
Customs Tariff Number: 85365080
GTIN-Code: 4013614343360
ETIM 8.0
Shunt release (for power circuit breaker):
Suitable for off-load switch: false
Suitable for overload relay: false
Type of electric connection: Screw connection
Rated control supply voltage Us at AC 50HZ: 350, 415 V
Rated control supply voltage Us at AC 60HZ: 350, 415 V
Rated control supply voltage Us at DC: 350, 500 V
Suitable for motor safety switch: true
Suitable for power circuit breaker: false
Initial value of the undelayed short-circuit release - setting range: 0 A
End value adjustment range undelayed short-circuit release: 0 A
Voltage type for actuating: AC/DC
Number of contacts as normally closed contact: 0
Number of contacts as normally open contact: 0
Number of contacts as change-over contact: 0
ETIM 9.0
Shunt release (for power circuit breaker):
Suitable for off-load switch: false
Suitable for overload relay: false
Type of electric connection: Screw connection
Rated control supply voltage AC 50 Hz: 350, 415 V
Rated control supply voltage AC 60 Hz: 350, 415 V
Rated control supply voltage DC: 350, 500 V
Suitable for motor safety switch: true
Suitable for power circuit breaker: false
Initial value of the undelayed short-circuit release - setting range: 0 A
End value adjustment range undelayed short-circuit release: 0 A
Voltage type for actuating: AC/DC
Number of contacts as normally closed contact: 0
Number of contacts as normally open contact: 0
Number of contacts as change-over contact: 0
eclass
27-37-04-18 - Full load current trip:
max. rated control supply voltage Us: 350, 415 V
min. rated control voltage Us with AC 50 Hz: 350, 415 V
min. rated control voltage Us with AC 60 Hz: 350, 415 V
min. rated control voltage Us with DC: 350, 500 V
Lowest value of setting range for short circuit tripper, undelayed: 0 A
Greatest value of tuning range short circuit tripper, undelayed: 0 A
Number of breaking contacts: 0
Number of changers: 0
Number of making contacts: 0
Type of actuation: AC/DC
suitable for power circuit breakers: false
suitable for power switches: false
suitable for protective motor switches: true
suitable for overload relays: false
Design of electrical connection: Screw connection