Catalog navigation
All catalogs
Geometric Search
Sketch Search
Variable Search
CAD model selection
PRODUKTABBILDUNG
Produktabbildung
ARTICLE_ID
Article number
2207255
ARTICLE_NAME
Type code
Yonos GIGA2.0-D 50/1-13/M-1,5
LOD
350
300
200
MANUFACTURER_NAME
Manufacturer
WILO SE
DESCRIPTION_SHORT
Short text
Very energy efficient in-line pump with IE5 motor (0.37 – 7.5 kW) or IE4 motor (11 – 22 kW) and electronic power adjustment in glanded pump design. Version as single-stage low-pressure centrifugal pump with flange connection and mechanical seal.
DESCRIPTION_LONG
Tender text
In-line pump with high energy efficiency with EC motor of energy efficiency class IE5 in accordance with IEC 60034-30-2, hydraulics with minimum efficiency index MEI ≥ 0.4 and electronic power adjustment in glanded pump design. The pump is configured as a single-stage low-pressure centrifugal pump with flange connection and mechanical seal. The Yonos GIGA2.0-D has been predominantly designed for pumping heating water (acc. to VDI 2035), chilled water and water-glycol mixtures without abrasive substances in heating, air conditioning and cooling systems. Design: *Single-stage low-pressure centrifugal pump with one-piece shaft in close-coupled design *Spiral housing in in-line design (suction and discharge ports with the same flanges in a line) *PN 16 flange – in accordance with EN 1092-2 *Pressure measuring connections (R 1/8) for mounted differential pressure sensor (version ...-R1 without differential pressure sensor) *Pump housing and lantern/motor flange with cataphoretic coating as standard *Mechanical seal for water pumping up to Tmax = +120 °C or +140 °C (depending on the pump type). A glycol admixture of 20% to 40% by volume is permitted up to T ≤ +40 °C. An alternative mechanical seal must be provided in water-glycol mixtures with glycol proportions > 40 % up to max. 50 % by volume and a fluid temperature of > +40 °C up to max. +120 °C or fluids other than water. When using water-glycol mixtures, the use of an S1 variant with a corresponding mechanical seal is generally recommended. *Connection voltages: **3~440 V ±10 % 50/60 Hz; 3~400 V ±10 % 50/60 Hz; 3~380 V -5 % +10 % 50/60 Hz **Version M-: 1~220 V … 240 V (±10%), 50/60 Hz *Compliance with electromagnetic compatibility without additional measures **Interference emission for residential environment according to EN 61800-3:2018 **Interference immunity for industrial environments according to EN 61800-3:2018 Control modes: *Variable differential pressure (dp-v) *Constant differential pressure (dp-c) *Constant speed (n-const.) *User-defined PID control Functions: *Operating modes of twin-head pump: Main/standby operation, efficiency-optimised parallel operation for dp-c and dp-v *Integrated full motor protection Display in the "Home screen" of the graphic display: *Control mode currently set *Current setpoint *Current actual value *Current volume flow (only if a differential pressure sensor is connected) *Current power consumption Version: *1 analogue input: 0 ... 10 V, 2 ... 10 V, 0 ... 20 mA, 4 ... 20 mA only for sensor value from differential pressure sensor *1 analogue input: 0 ... 10 V, 2 ... 10 V, 0 ... 20 mA, 4 ... 20 mA only for external setpoint sensor *1 digital input (Ext. OFF) *2 Signal relays for run signals and fault messages *Slot for Wilo-CIF modules with interfaces for building automation (BA) (optional accessories: CIF modules Ethernet, Modbus RTU, BACnet MS/TP, LON, PLR, CAN) *Wilo Net as Wilo system bus for communication during dual-pump operation *Automatic emergency operation with definable pump speed for exceptional circumstances, e.g. bus communication or sensor value malfunction *Rotatable, graphic colour display (2 inches) with one button manual operation level *Integrated dual-pump management (twin-head pumps are prewired) connection via Wilo Net *Cable break detection when using an analogue signal (in connection with 2 ... 10 V or 4 ... 20 mA) *Standard condensate drainage holes in the motor housing (closed upon delivery) *Air vent valve on the lantern Scope of delivery: *Pump *Installation and operating instructions and declaration of conformity Accessories must be ordered separately: 3 mounting brackets with fixation material for installation on a base *Blind flanges for twin-head pump housing *For connection to building automation: **CIF module PLR **CIF module LON **CIF module BACnet MS/TP **CIF module Modbus RTU **CIF module CANopen **CIF module Ethernet Multi-protocol (Modbus TCP, BACnet/IP) **Connection M12 RJ45 CIF Ethernet *Differential pressure sensor DPS 2 ... 10 V *Differential pressure sensor DPS 4 ... 20 mA
PRODUCT_DESCRIPTION
Product description
ETIM_CLASS__EC_
ETIM Class (EC)
EF023038
Pump casing material
EF023143
Quality class of pump casing
EF011652
Material pump wheel
EF024149
Material pump wheel
EF014904
Volume flow rate (BEP)
m³/h
EF014905
Head at flow rate (BEP)
kPa
EF000991
Max. discharge flow
m³/h
EF000992
Max. static height
m
EF020449
Max. operating pressure
bar
EF023090
Double pump
EF003701
Electrical connection
EF000536
Cable length
mm
EF003977
Rated voltage
V
EF000351
Number of phases
EF005455
Frequency
Hz
EF000001
Nominal current
A
EF012424
Motor power input (P1) per motor
kW
EF012425
Motor power output (P2) per motor
kW
EF010779
Pump power consumption (solpump)
W
EF010780
Pump power consumption standby (solstandbypump)
W
EF013710
Minimum Efficiency Index (MEI)
EF023092
Insulation class acc. to IEC
EF001642
Rotational speed
1/min
EF020121
Motor speed control
EF020120
Type of speed control
EF023093
Motor with extended shaft
EF015266
Communication
EF007178
Radio standard Bluetooth
EF007179
Radio standard 2G / 3G / 4G
EF016383
Radio standard 2G / 3G / 4G
EF016385
Radio standard 5G
EF016386
Interface signal 0-10 V / 2-10 V
EF016387
Interface signal 0-20 mA / 4-20 mA
EF016388
Interface PT100 / PT1000 / PTC
EF016389
Interface Pulse Width Modulation (PWM)
EF016390
Interface pulse counter
EF003626
Potential free switch contact
EF007314
With communication interface RS-485
EF007312
With communication interface RS-232
EF007521
Supporting protocol for EtherNet/IP
EF003055
Supporting protocol for KNX
EF003052
Supporting protocol for PROFIBUS
EF007525
Supporting protocol for PROFINET IO
EF016391
Supporting protocol for CAN/CANOpen
EF016392
Supporting protocol for Modbus TCP
EF016393
Supporting protocol for Modbus RTU
EF016394
Supporting protocol for BACnet MS/TP
EF016395
Supporting protocol for BACnet IP
EF016396
Supporting protocol for LON/LONWorks
EF016397
Supporting protocol for LIN Bus
EF023182
Medium temperature (continuous)
°C
EF002386
Ambient temperature
°C
EF025116
Connection on supply side
EF025117
Diameter of connection on supply side
EF025503
Outer pipe diameter connection inlet side
mm
EF026143
Flange compression stage connection inlet
bar
EF014906
Connection standard inlet side
EF025977
Connection outlet side
EF025118
Diameter of connection on delivery side
EF025504
Outer pipe diameter connection outlet side
mm
EF026233
Flange compression stage connection outlet
bar
EF014907
Connection standard outlet side
EF001339
Flange shape
EF004265
Recess length
mm
EF005474
Degree of protection (IP rating)
EF020038
Self-priming
EF004663
Explosion-proof
EF014908
Standard motor
EF014979
Motor efficiency class
MECHANICAL_SEAL
Mechanical seal
EF023103
With oval counterflanges
no
A1
Angle to first bolt hole
45.0 °
A2
Angle to first bolt hole
45.0 °
A3
Angle electrical cabinet 1
315
A4
Angle electrical cabinet 2
45
B1
Thickness flange (incl. sealing edge)
20 mm
B2
Thickness flange (incl. sealing edge)
20 mm
D1
Outer diameter of flange
165 mm
D2
Outer diameter of flange
165 mm
D21
Diameter bolt hole
19 mm
D22
Diameter bolt hole
19 mm
D41
Diameter sealing edge
99 mm
D42
Diameter sealing edge
99 mm
DM
Diameter motor
130 mm
DN1
Nominal inner diameter
50 mm
DN2
Nominal inner diameter
50 mm
DO1
Outer pipe diameter connection
56 mm
DO2
Outer pipe diameter connection
56 mm
F1
Thickness sealing edge
3 mm
F2
Thickness sealing edge
3 mm
H5
Centre-to-centre (double) pump
250 mm
HD
Diameter pump housing
262 mm
K1
Pitch circle
125 mm
K2
Pitch circle
125 mm
L1
Connection length
150 mm
L2
Connection length
190 mm
LE1
Height pump housing
141 mm
LE2
Centre connection to end motor
311 mm
LE3
Length electrical cabinet
347 mm
LE4
Distance connection to beginning of motor
0.0 mm
LE5
Distance to centre connection
87 mm
LE6
Distance connection to electrical cabinet
98 mm
LE7
Length to top side electrical cabinet
246 mm
LE8
Width electrical cabinet
234 mm
LE9
Length to top side electrical cabinet 2
246 mm
LE10
Width electrical cabinet 2
234 mm
N1
Number of bolt holes
4
N2
Number of bolt holes
4
Z1
Working length
150 mm
Z2
Working length
190 mm
BMAX
Dimensions
737 mm
DIAMD1
Dimensions
188.0 mm
H1
Dimensions
0.0 mm
X
Dimensions
300 mm
DA1
Dimensions
0.000 mm
C
Dimensions
240.000 mm
D3
Dimensions
25.000 mm
S1
Dimensions
10.000 mm
S2
Dimensions
20.000 mm
Y1
Dimensions
132.000 mm
Y2
Dimensions
48.000 mm
FD
Dimensions
87
L5
Dimensions
90.000 mm
LA
Dimensions
10.000 mm
LC
0
AUHVACINST
HVAC Installation Australia
LC2
15.0
LD1
188.000 mm
HB1
Dimensions
121 mm
HB2
Dimensions
131 mm
FEETPOSITION
Position of feet on pumphousing
1
Preview - Generation

Embedded user actions
0