116023 SWD4-8MF2
Blade terminal, SmartWire-DT, on ribbon-cable end for connecting coordinator etc.
EL Number (Norway)
4519789
SmartWire-DT blade terminal, 8 pole, is attached to both ends of the SWD ribbon cable. The following component can be attached: SmartWire-DT coordinators such as easy800 SWD/SWD Gateway, SWD-Power feeder module, SWD coupling, SWD bus termination
General specifications
Product name
Eaton SWD4 Accessory Blade terminal
Part no.
SWD4-8MF2
EAN
4015081157631
Product Length/Depth
8 millimetre
Product height
18 millimetre
Product width
23 millimetre
Product weight
0.002 kilogram
Certifications
CSA File No.: 2324643
UL Category Control No.: NKCR
UL
CSA Class No.: 3211-07
UL File No.: E29184
CSA
UL Category Control No.: NKCR
UL
CSA Class No.: 3211-07
UL File No.: E29184
CSA
Product Tradename
SWD4
Product Type
Accessory
Product Sub Type
Blade terminal
Catalog Notes
not relevant
Features & Functions
Functions
For connecting the ribbon cable to the gateway, power feeder module, coupling, SWD4-RC8-10 bus termination resistor
General information
Degree of protection
IP20
IP20 (according to IEC/EN 60529, EN 50178, VBG 4)
IP20 (according to IEC/EN 60529, EN 50178, VBG 4)
Product category
SmartWire-DT accessories
Ambient conditions, mechanical
Constant acceleration
1 g, 8.4 - 150 Hz, according to IEC/EN 61131-2, Vibrations
Constant amplitude
3,5 mm, 5 - 8.4 Hz, according to IEC/EN 61131-2, Vibrations
Mounting position
As required
Shock resistance
15 g, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 11 ms, 9 Impacts
Climatic environmental conditions
Air pressure
795 - 1080 hPa (operation)
Ambient operating temperature - min
-25 °C
Ambient operating temperature - max
105 °C
Ambient storage temperature - min
-40 °C
Ambient storage temperature - max
105 °C
Climatic proofing
Dry heat to IEC 60068-2-2
Damp heat, constant, to IEC 60068-2-3
Damp heat, constant, to IEC 60068-2-3
Environmental conditions
Condensation: prevent with appropriate measures
Operating temperature - min
-25 °C
Operating temperature - max
105 °C
Relative humidity
5 - 95 % (non-condensing, IEC/EN 60068-2-30)
Electrical rating
Power loss
0 W
Communication
Connection to SmartWire-DT
Yes
Connection type
Socket, 8-pole
Input/Output
Number of insertion cycles
200
Design verification
Equipment heat dissipation, current-dependent Pvid
0 W
Heat dissipation capacity Pdiss
0 W
Heat dissipation per pole, current-dependent Pvid
0 W
Rated operational current for specified heat dissipation (In)
0 A
Static heat dissipation, non-current-dependent Pvs
0 W
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Meets the product standard's requirements.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Technical data ETIM 9.0
Programmable logic controllers PLC (EG000024) / Accessories/spare parts for controls (EC002584)
Electric engineering, automation, process control engineering / Display and control component / Panel (HMI) / Panel (HMI, accessories) (ecl@ss13-27-33-02-92 [AFX005008])
Type of electrical accessory/spare part
Plug
Type of mechanical accessory/spare part
Other
Accessory
Yes
Spare part
No
-
(Web)
-
Asset
-
Asset
-
Asset
-
Asset
-
Asset
-
Asset
-
Asset
-
Eaton EMEA Download-Center - download data for this item
-